| [캐나다] 캘거리 하·폐수처리 플랜트, Hydro International 모래제거시스템 활용
Bonnybrook 하·폐수처리 플랜트는 선진적 모래 관리(Advanced Grit Management) 시스템을 설치함으로써 Hydro International에 의한 많은 양의 모래를 제거하는 등 지금까지 전 세계적으로 운영 효율에 있어 본질적인 기여를 해왔다. 완전히 새로운 두수공(headworks) 시설은 유입 폐수처리 시 후류 공정(downstream process) 보호에 대한 모래 마모 및 퇴적 과정에서 필요했다.
[원문보기]
Calgary Wastewater Treatment Plant employs Hydro International grit removal system
The City of Calgary’s Bonnybrook Wastewater Treatment Plant has installed the largest Advanced Grit Management®system ever supplied worldwide by Hydro International to effectively remove large amounts of grit as an essential contribution to operating efficiency.
A complete new headworks facility was needed to treat incoming wastewater and protect downstream processes from grit abrasion and deposition. Hydro International supplied a grit removal solution that could be built in the limited space available and cope with the unique characteristics of the influent at Bonnybrook, including wide variations in flow caused by dry summers and peak winter thaw.
Ten HeadCell® units, ten SlurryCupTM grit classifiers and five Grit Snail® dewatering units will treat a peak flow rate of 1,390 megaliters/day (368 MGD). The system is guaranteed to remove 95% of all grit 150 micron and larger at peak flow, and 95% of all grit 75 micron and larger, at an average flow of 418 megaliters/day (110 MGD).
Senior Project Engineer Zorica Knezevic, City of Calgary Water Resources, states: "High performance grit removal is important for lower operation and maintenance costs and retaining the specified capacity of downstream process units, such as bioreactors, fermenters and digesters."
Grit removal is particularly important to Calgary’s wastewater treatment given the city’s climate and topography with a high portion of grit arriving in the raw sewage during spring/early summer storm events.
Consultant engineering firm Stantec was hired to design the new headworks and pre-qualify the suppliers.
"The Bonnybrook WWTP project comprises the replacement of the complete headworks facility. We included maintenance costs in the lifecycle evaluation of technology options and project justification," explains Ryan Roberts, P.Eng., PMP, Vice President - Water for Stantec.
"The project scope included screening and grit removal; screening washing and compacting; grit classification and dewatering; solids conveyance and storage; and flow distribution and measurement.
"As the removal efficiency of the existing aerated grit tanks was low, and passed on much grit to accumulate in downstream processes, grit characterization had already been assessed by the City in a separate exercise. This was necessary to develop an accurate design basis for a cost-benefit evaluation of the various treatment alternatives considered."
A grit characterization study was performed to determine plant influent grit gradation and settling velocity as well as a performance evaluation of the existing aerated grit chamber system.
The study found that the existing grit system was removing only 26-29% of the influent grit. The study also identified the reason: virtually all of the influent grit had a settling velocity lower than that of a 212 micron sphere of clean sand, a conventional design point, for which the original grit system was designed. By having the native grit settling velocity, the City and Stantec were able to develop the new system performance requirements and solicit proposals to meet their specific needs.
[출처 = Water World / 2016년 4월 21일] |